Portafolio de Separation Systems Labins


Product DescriptionPart,NumberTest Methods Reference
GC Columns  
Packed column for ASTM D3710, D2887, D5307SD-001D3710, D2887, D5307
Wide bore (530u) capillary column for ASTM D2887; 10MSD-002-2D2887, D5307
Wide bore (530u) column for D2887; 5MSD-002-5MD2887
Wide bore (530u) capillary column for ASTM D7213/D2887 for 'Extended' AnalysisSD-002-EX2D7213, D2887
Wide bore (530u) capillary column for D2887 'High Temp' method; 12MSD-002-HTBD2887
Column for D2887 for 'Accelerated' methodSD-002-HTC5D2887
Column (metal clad) for D7169/D7213SD-002-HTE2D6352, D7169, D7213, D7500
Column (metal clad) for high temp simulated distillation; crude oilSD-002-HTE3D7169
Wide bore (530u) column for D7096SD-003D7096
Ultra-high resolution capillary column for DHA/PIANO analysis; (100M)SD-009D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Refinery Gas Analyzer Column Set - For Separation Systems RGA systemSS-115-900-300-00Refinery Gas Analysis (RGA)
   
Calibration Standards and Reference Materials  
Internal standard for LUBE C10-C12; 25mlSD-004LUBE Method
Spiking kit includes C8 to C20 (even) + C40SD-004-SPKLUBE Method
Internal Standard for D5307; C14-C17 ; 25ml bottleSD-005D5307
Retention time standard for D2887 6 X 1ml ampoulesSD-006D2887
Response factor standard for D7096/D3710; 6 X 1ml ampoulesSD-007D7096, D3710
Retention time standard for D7096/D3710; 6 X 1ml ampoulesSD-008D7096, D3710
Reference Gas Oil Lot #2, 25 ml bottleSD-016-02D2887
Reference Gas Oil Lot #2; 5 ml vialSD-016-05D2887
5010 reference material; 25ml bottleSD-020-01CD7169, D6352, D7500
5010 reference material; 5ml vialSD-020-02D7169, D6352, D7500
Gravimetric standard for use in DHA-FID/MSSD-028MSD5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Standard to set valve timing on DHA pre-fractionatorSD-040D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Calibration standard for DHA/PIANO; pack of 6 X 1ml ampoulesSD-053D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Calibration standard for DHA/PIANO; 1ml ampouleSD-053-005D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Calibration standard (naphtha blend) for DHA/PIANO with oxygenates; 6 X 1ml ampouleSD-053-010D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Calibration standard (naphtha blend) for DHA/PIANO with oxygenates; 1ml ampouleSD-053-020D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Calibration standard (naphtha blend with gases) for DHA/PIANO; 1 ml ampouleSD-053-WGD5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Gravimetric standard for DHA; 1 ml ampouleSD-053-030D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Calibration standard kit consisting of light naphtha, heavy naphtha, akylate, reformate feed, reformate product, light cracked naphtha and heavy cracked naptha matrices; 8 X 1 ml ampoulesSD-053-KITD5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Calibration standard for D7096 without ethanolSD-060-05D7096
Calibration (curve) standard for D5501; 6 X 1 ml ampoulesSD-ASTM-D5501-01D5501
"Daily" check standard for D5501; 6 X 1ml ampoulesSD-ASTM-D5501-03D5501
Standards kit for D5501SD-ASTM-D5501-05D5501
Calibration standard for D7096/D3710 (per Marathon Oil protocol)SD-MAPLLC-010D3710
Retention time standard for D2887; 10% C12; 6 X 1 ml ampoulesSD-SS3E-01D2887
Retention time standard for D2887; 1% C12; 6 X 1 ml ampoulesSD-SS3E-02D2887
Retention time standard; C3-C19 and 2 X C20-C44 in carbon disulfide; 6 X 1 ml ampoulesSD-SS3E-02-2X-WGD2887
Retention time standard for D2887; 6 X 1 ml ampoulesSD-SS3E-02WGD2887
Retention time standard for D7213 C12/Polywax 500; 6 X 1ml ampoulesSD-SS3E-03D7213
Retention time standard for D7169; C5-C18 Polywax 655; 10:1 CS2; 6 X 1ml ampoulesSD-SS3E-05D7169
Response factor standard for D7169; 6 X 1ml ampoulesSD-SS3E-05QD7169
Retention time standard for D6352; C10-26 Polywax 655; 6 X 1 ml ampoulesSD-SS3E-06D6352
Calibration standard - ASTM D4815SS-ASTM D-4815D4815
Calibration standard - ethanol, methyl ether and methyl formate in methanolSS-TESTMIX108D5501
Calibration standard - C4 alcohols in methanolSS-TESTMIX110-01D5501
   
Inlet Liners  
Glass inlet liners for SimDis® Inlet; 5/PKSS-035-00D2887, D5307, D6352, D7169, D7500
Glass liners for SimDis® Inlet for fast simdis method; 5/PKSS-035-00.1D2887, D5307, D6352, D7169, D7500
Glass inlet liners for Agilent Split/Splitless capillary inlet; DHA; 5/PKSS-035-05D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Glass inlet liner for Separation Systems pre-fractionator (early design)SD-013BD5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Glass inlet liner for Separation Systems pre-fractionating inlet (new design)SD-013CD5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Nuts and Ferrules  
Nut for SimDis® Inlet; 2/PKSS-032-00D2887, D3710, D5307, D6352, D7096, D7169, D7500
Ferrules for SimDis® Inlet; 10/PKSS-030-20D2887, D3710, D5307, D6352, D7096, D7169, D7500
Ferrules for use with FID for high temperature simulated distillation - Detector side; 10/PKSS-030-20DD6352, D7096, D7169, D7500
Ferrules for DHA/PIANO methods for use with S/S capillary inlet; 10/PKSS-030-35D5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Ferrules for DHA/PIANO methods; detector side of column, 10/PKSS-030-35DD5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
   
High Performance Septa  
Septa for use with SimDis® Inlet inlet; 25/PKSS-031-00D2887, D3710, D5307, D6352, D7096, D7169
Septa for use for simulated distillation and PIANO; 25/PKSS-031-00CONVD5134, D6729, D6730, D6733, D7900, IP344-88, Fast DHA, DHA Front End
Gas Filters/Traps  
Hydrocarbon trap for carrier gas; 100cc with 1/8" fittingsSS-350-001All
Oxygen/Hydrocarbon Filter KitSS-350-003All
Oxygen indicating moisture trap (50cc)SS-350-005All
Sulfur TrapSS-350-008Sulfur Analysis Methods
   
Miscellaneous  
FID flame jet for high temp simulated distillationSD-011-01D6352, D7169, D7213
   
NOTA: No se traen estandares en disulfuro de carbono (CS2)